Papagou, Greece
Code: CS2
A 1970s single family house with a treated floor area of 150m2, an uninsulated brick façade, 20m of balconies, a flat, uninsulated roof and a floor slab that is 2.4m above ground. The windows are double-glazed with aluminium frames that are not thermally broken. The building is quite leaky with an airtightness level of n50 8 ACH (as compared to 0.6 ACH for the Passive House Standard).
Retrofit completed. Monitoring post-renovation is now underway.
EnerPHit Energy Demand Method. This means that we will achieve EnerPHit level energy demanf (25 kWh/m2a) certification by insulating the entire envelope, minimsing existing themal bridges, replacing windows, improving airtightness and installing mechanical ventilation with heat recovery.
Renovation will reduce the heating demand by factor of 15 and the cooling demand by a factor of 6.
TFA | existing treated floor area (usable floor space) |
150.0 m2 |
---|---|---|
Space heating | Heating demand |
531.0 kWh/(m2a) |
Heating load |
239.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
101.15 kWh/(m2a) |
Cooling load |
111.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.1 % |
|
Airtightness | Pressurization test result n50 |
8.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
777.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
1386.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
TFA | existing treated floor area (usable floor space) |
150.0 m2 |
---|---|---|
Space heating | Heating demand |
35.18 kWh/(m2a) |
Heating load |
21.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
17.51 kWh/(m2a) |
Cooling load |
15.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
103.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
57.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
yes |
Two family house
150 m2
Aris Georgopoulos
HPHI
Certified
80 000 €
Sofia Piperou
Hellenic Passive House Institute (HPHI)
Téléphone: +30 211 4081109
E-Mail: info@eipak.org