Maroussi, Greece
Code: CS4
A 1970s three family apartment with 312m2 of treated floor area, an uninsulated roof, 50m of balconies and an only lightly insulated brick façade. The windows are double-glazed with aluminium frames that are not thermally broken. The building has a low airtightness level of n50 = 5 ACH (as compared to 0.6 ACH for the Passive House Standard).
After completion, the building will be the first multifamily EnerPHit in Athens.
EnerPHit Energy Demand Method. This means that we will achieve EnerPHit level energy demanf (25 kWh/m2a) certification by insulating the entire envelope, minimsing existing themal bridges, replacing windows, improving airtightness and installing mechanical ventilation with heat recovery.
Renovation will reduce the heating demand by factor of 10 and the cooling demand by a factor 3.
TFA | existing treated floor area (usable floor space) |
312.0 m2 |
---|---|---|
Space heating | Heating demand |
143.12 kWh/(m2a) |
Heating load |
72.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
30.44 kWh/(m2a) |
Cooling load |
35.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.0 % |
|
Airtightness | Pressurization test result n50 |
8.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
365.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
221.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
TFA | existing treated floor area (usable floor space) |
312.0 m2 |
---|---|---|
Space heating | Heating demand |
15.12 kWh/(m2a) |
Heating load |
11.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
12.21 kWh/(m2a) |
Cooling load |
9.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
3.0 % |
|
Airtightness | Pressurization test result n50 |
0.9 /h |
Non-renewable Primary Energy (PE) | PE demand |
74.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
43.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
Multi family dwelling
312 m2
Spyros Mavromatis
Hellenic Passive House Institute (HPHI)
Finished
98 000 €
Alexandra Mangina
Hellenic Passive House Institute (HPHI)
Téléphone: +30 211 4081109
E-Mail: info@eipak.org