Cholargos, Greece
Code: CS3
A 1980s multifamily house with a treated floor area of 1500m2, a lightly insulated brick façade, 150m of balconies, a flat, uninsulated roof and a floor slab that is 2.4m above ground. The windows are double-glazed with aluminium frames that are not thermally broken. The building is quite leaky with an airtightness level of n50 = 8 ACH (as compared to 0.6 ACH for the Passive House Standard).
Monitoring post-renovation is now underway.
EnerPHit Energy Demand Method. This means that we will achieve EnerPHit level energy demand (25 kWh/m2a) certification by insulating the entire envelope, minimsing existing themal bridges, replacing windows, improving airtightness and installing mechanical ventilation with heat recovery.
This project will be carried out as a step by step renovation.
Renovation will reduce the heating demand by factor of 17.5 and the cooling demand by a factor 3.5.
TFA | existing treated floor area (usable floor space) |
140.0 m2 |
---|---|---|
Space heating | Heating demand |
210.0 kWh/(m2a) |
Heating load |
93.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
41.0 kWh/(m2a) |
Cooling load |
41.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
91.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
591.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
352.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
TFA | existing treated floor area (usable floor space) |
140.0 m2 |
---|---|---|
Space heating | Heating demand |
12.0 kWh/(m2a) |
Heating load |
10.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
12.0 kWh/(m2a) |
Cooling load |
10.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
3.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
89.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
43.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
Multi family dwelling