Case Studies

Single Family House Renovation, Papagou

Papagou, Greece

Code: CS2

View from the outside
© HPHI
New PVC window installation
© HPHI
New PVC window installation
© HPHI

Original situation

A 1970s single family house with a treated floor area of 150m2, an uninsulated brick façade, 20m of balconies, a flat, uninsulated roof and a floor slab that is 2.4m above ground. The windows are double-glazed with aluminium frames that are not thermally broken. The building is quite leaky with an airtightness level of n50 8 ACH (as compared to 0.6 ACH for the Passive House Standard).

Renovation approach

Retrofit completed. Monitoring post-renovation is now underway.

Renovation approach document

Modernisation proposal

EnerPHit Energy Demand Method. This means that we will achieve EnerPHit level energy demanf (25 kWh/m2a) certification by insulating the entire envelope, minimsing existing themal bridges, replacing windows,  improving airtightness and installing mechanical ventilation with heat recovery.

Efficiency improvement

Renovation will reduce the heating demand by factor of 15 and the cooling demand by a factor of 6.

PHPP verification sheet before retrofit

TFA existing treated floor area (usable floor space)

150.0 m2

Space heating Heating demand

531.0 kWh/(m2a)

Heating load

239.0  W/m2

Space cooling Cooling & dehum. demand

101.15 kWh/(m2a)

Cooling load

111.0 W/m2

Frequency of overheating (> 25 °C)

– %

Frequency of excessively high humidity (> 12 g/kg)

0.1 %

Airtightness Pressurization test result n50

8.0 /h

Non-renewable Primary Energy (PE) PE demand

777.0 kWh/(m2a)

Primary Energy Renewable (PER) PER demand

1386.0 kWh/(m2a)

Generation of renewable energy (in relation to projected building footprint area)

– kWh/(m2a)

EnerPHit classic

no

PHPP verification sheet after retrofit

TFA existing treated floor area (usable floor space)

150.0 m2

Space heating Heating demand

35.18 kWh/(m2a)

Heating load

21.0  W/m2

Space cooling Cooling & dehum. demand

17.51 kWh/(m2a)

Cooling load

15.0 W/m2

Frequency of overheating (> 25 °C)

– %

Frequency of excessively high humidity (> 12 g/kg)

0.0 %

Airtightness Pressurization test result n50

1.0 /h

Non-renewable Primary Energy (PE) PE demand

103.0 kWh/(m2a)

Primary Energy Renewable (PER) PER demand

57.0 kWh/(m2a)

Generation of renewable energy (in relation to projected building footprint area)

– kWh/(m2a)

EnerPHit classic

yes

Video

Click to view via Youtube (Google)

Herunterladen

Link of materials related to the project that could be useful and/or of interest

Key facts

Building typology

Two family house

Existing treated floor area (usable floor space)

150 m2

Building owner

Aris Georgopoulos

Consulting outphit partner

HPHI

Project status

Certified

Overall budget

80 000 €