Bagnères de Bigorre, France
Code: CS7
A four storey non-residential building from the 1830s located in the dense city centre of Bagnères de Bigorre in the Pyrenean piedmont (FR-65000).
Originally built as a maison, the building was separated into 5 flats and now, after renovation, it will be used as a hotel.
Just finished checking structural integrity in preparation for the retrofit; likely finsihed in 2024, started in 2022.
Semi prefabricated complete retrofit to the EnerPHit Standard. The front side will be a traditional retrofit, since the building is listed, with vacuum insulation on the inside of the wall. The back side will be a prefabricated, compressed straw wall (Ecococon Wall). The bottom is being dug out from the inside of the building for a depth of 50cm. The soil will be subsequently replaced with foamglas. New triple glazed windows, heat pumps and ventilation with heat recovery will be added. Also collecting 50% of the heat from grey water.
The planned renovation will bring heating demand down by a factor of more than 20 and also result in an impressive reduction in total primary energy.
TFA | existing treated floor area (usable floor space) |
250.0 m2 |
---|---|---|
Space heating | Heating demand |
354.0 kWh/(m2a) |
Heating load |
114.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
0.0 kWh/(m2a) |
Cooling load |
0.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
0.0 % |
|
Frequency of excessively high humidity (> 12 g/kg) |
1.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
455.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
881.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
TFA | existing treated floor area (usable floor space) |
250.0 m2 |
---|---|---|
Space heating | Heating demand |
15.0 kWh/(m2a) |
Heating load |
8.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
0.0 kWh/(m2a) |
Cooling load |
0.0 W/m2 |
|
Frequency of overheating (> 25 °C) |
10.0 % |
|
Frequency of excessively high humidity (> 12 g/kg) |
5.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
26.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
12.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
no |
Multi family dwelling
250 m2
Adourable Bagnères SARL
PROPASSIF
Construction phase
400 000 €
Etienne Vekemans
CEO
PROPASSIF
Telefon: 0145081335