1960s concrete non-residential building on the outskirts of Lons le Saunier. The building is used by AJENA as a centre for training on retrofitting, so a well renovated building would be a big plus.
A prefabricated wall to the north (windowless) and on the south wall, wooden caissons (boxes) mounted onsite to support the insulation. Ventilation with high performance heat recovery. Increased airtightness throughout and reduced thermal bridging to be achieved through the use of prefab elements and exterior insulation.
A complete energy retrofit to EnerPHit level using some prefabricated elements: a prefabricated North wall and South wall that will be mounted on-site. Triple glazing and ventilation with heat recovery will be added.
The improvement that an EnerPHit renovated building can offer is huge in this cold part of Jura near Geneva, reducing heating demand by a factor of 10.
TFA | existing treated floor area (usable floor space) |
285.0 m2 |
---|---|---|
Space heating | Heating demand |
342.0 kWh/(m2a) |
Heating load |
113.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
– kWh/(m2a) |
Cooling load |
– W/m2 |
|
Frequency of overheating (> 25 °C) |
9.0 % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
154.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
641.0 kWh/(m2a) |
TFA | existing treated floor area (usable floor space) |
285.0 m2 |
---|---|---|
Space heating | Heating demand |
25.0 kWh/(m2a) |
Heating load |
15.0 W/m2 |
|
Space cooling | Cooling & dehum. demand |
– kWh/(m2a) |
Cooling load |
– W/m2 |
|
Frequency of overheating (> 25 °C) |
8.0 % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
74.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
69.0 kWh/(m2a) |