Case Studies

Ajena

Lons le Saunier, France

Code: CS9

Before the renovation
© R. Claret, Ajena
After the renovation
© R. Claret, Ajena
Team meeting
© R. Claret, Ajena
Renovation info
© R. Claret, Ajena
During construction
© R. Claret, Ajena
Old heaters
© R. Claret, Ajena

Original situation

1960s concrete non-residential building on the outskirts of Lons le Saunier. The building is used by AJENA, “Association Jurassienne d’Energies reNouvelAbles", as a centre for training on retrofitting, so a well renovated building would be a big plus, making obsolete its old fuel heating system and giving more sense to renewable energy on top of the building.

 

Renovation approach

Monitoring post-renovation is now underway. The project's certification is now completed and will be awarded on September 23, 2023, during the building's inaugual ceremony.

 

Renovation approach document

Modernisation proposal

Internal Insulation on the “blind” north wall. On the south wall: mounted on site “wooden boxes” to hold insulation . Comfort ventilation with high performance heat recovery. Air tightness and reduction of thermal bridges.

Efficiency improvement

The improvement that an EnerPHit renovated building can offer is huge in this cold part of Jura near Geneva, reducing heating demand by a factor of 10.

PHPP verification sheet before retrofit

TFA existing treated floor area (usable floor space)

285.0 m2

Space heating Heating demand

342.0 kWh/(m2a)

Heating load

113.0  W/m2

Space cooling Cooling & dehum. demand

– kWh/(m2a)

Cooling load

– W/m2

Frequency of overheating (> 25 °C)

9.0 %

Frequency of excessively high humidity (> 12 g/kg)

0.0 %

Airtightness Pressurization test result n50

1.0 /h

Non-renewable Primary Energy (PE) PE demand

154.0 kWh/(m2a)

Primary Energy Renewable (PER) PER demand

641.0 kWh/(m2a)

Generation of renewable energy (in relation to projected building footprint area)

– kWh/(m2a)

EnerPHit classic

no

PHPP verification sheet after retrofit

TFA existing treated floor area (usable floor space)

285.0 m2

Space heating Heating demand

14.0 kWh/(m2a)

Heating load

12.0  W/m2

Space cooling Cooling & dehum. demand

– kWh/(m2a)

Cooling load

– W/m2

Frequency of overheating (> 25 °C)

11.0 %

Frequency of excessively high humidity (> 12 g/kg)

0.0 %

Airtightness Pressurization test result n50

1.0 /h

Non-renewable Primary Energy (PE) PE demand

101.0 kWh/(m2a)

Primary Energy Renewable (PER) PER demand

65.0 kWh/(m2a)

Generation of renewable energy (in relation to projected building footprint area)

– kWh/(m2a)

EnerPHit classic

no

Key facts

Building typology

Office | administration building

Existing treated floor area (usable floor space)

285 m2

Building owner

AJENA

Consulting outphit partner

PROPASSIF

Project status

Certified

Overall budget

550 000 €

Contact

Etienne Vekemans
CEO
PROPASSIF
Telefon: 0145081335
E-Mail: e.vekemans@propassif.fr