Madrid, Spain
Code: OP20
The original building, located in the city of Madrid, consists of two independent volumes separated by a central courtyard and connected through the basement floor, which is out of the thermal envelope.
The main building has five floors, and the second building has three floors. The main building has a protected historic façade, making implementing the airtight layer difficult.
The building from 1903 was retrofitted in 1986 using a traditional construction system.
Construction works in progress. EnerPHit certification in progress.
In this retrofit, the EnerPHit standard will be achieved through the Energy Demand Method. It is a complete renovation, including the following actions:
No calculations available for the existing building yet, no monitoring results available.
TFA | existing treated floor area (usable floor space) |
3231.51 m2 |
---|---|---|
Space heating | Heating demand |
1.0 kWh/(m2a) |
Heating load |
– W/m2 |
|
Space cooling | Cooling & dehum. demand |
15.0 kWh/(m2a) |
Cooling load |
– W/m2 |
|
Frequency of overheating (> 25 °C) |
– % |
|
Frequency of excessively high humidity (> 12 g/kg) |
0.0 % |
|
Airtightness | Pressurization test result n50 |
1.0 /h |
Non-renewable Primary Energy (PE) | PE demand |
72.0 kWh/(m2a) |
Primary Energy Renewable (PER) | PER demand |
41.0 kWh/(m2a) |
Generation of renewable energy (in relation to projected building footprint area) |
– kWh/(m2a) |
|
EnerPHit classic |
yes |